Kyocera ECOSYS M2040dn error C7800: outer thermistor broken
Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw
Quick answer
Kyocera ECOSYS M2040dn error C7800 means the temperature/humidity sensor, also called the outer or external thermistor, is giving a value above its limit. The first suspect is the sensor connector on the main/engine PWB. Restart the printer once, then call a technician if the code comes back.
What does C7800 mean?
The temperature/humidity sensor reads the outside temperature and humidity for the printer. C7800 appears when the sampled value from it goes past the reference value. The manual checks the wiring, then the sensor, then the main board. The same code and the same checks apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, because Kyocera covers all of them in one service manual.
What causes C7800?
Loose connector or damaged wire
The lead from the temperature/humidity sensor to the main/engine PWB (YC2) is not making good contact.
Faulty temperature/humidity sensor
The sensor itself has failed.
Main/engine PWB fault
The main control board is faulty. The manual lists this last.
What can you check yourself?
- 1
Restart once
Switch the printer off at the power switch, wait a few seconds and switch it on again. Note the code shown.
- 2
If the code returns
Leave the printer off and call a technician. The remaining checks are inside the machine.
Steps for a technician
- 1
Check the connection
Clean the contacts and refit the connector between the temperature/humidity sensor and the main/engine PWB (YC2). Fit a new wire if there is no continuity.
- 2
Replace the sensor
If the code stays, fit a new temperature/humidity sensor.
- 3
Replace the main/engine PWB
As the final step, fit a new main/engine PWB.
Need a part for this?
The store does not list the temperature/humidity sensor named for this code, so please ask on WhatsApp for availability.
Ask on WhatsApp: +91 88899-15080When should you call a technician?
Call a technician if C7800 shows again after one restart. The checks need the sensor wiring and the main board reached.
Questions people ask
- What does error C7800 mean on a Kyocera M2040dn?
- On a Kyocera ECOSYS M2040dn, C7800 means outer thermistor broken. The reading from the temperature/humidity sensor is beyond its reference value.
- How do I fix Kyocera C7800?
- A technician reseats the sensor connector at YC2 on the main/engine PWB, then fits a new temperature/humidity sensor if needed, and replaces the main/engine PWB last.
- Where is the outer thermistor on a Kyocera M2040dn?
- The service manual shows the temp/humid sensor on the left side of the machine, near the scanner motor and the fuser pressure release motor.
- Is Kyocera C7800 the same as C7220?
- No. C7800 is the outside temperature/humidity sensor, while C7220 is the sensor that reads the temperature inside the printer.