C7220Service codeCritical: machine stops

Kyocera ECOSYS M2040dn error C7220: broken in-machine thermistor

Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw

Quick answer

Kyocera ECOSYS M2040dn error C7220 means the in-machine temperature sensor, which reads the temperature inside the printer, is giving a value above its limit, so the printer reports a broken thermistor. The first suspect is its connector on the main/engine PWB. Restart once, then call a technician.

What does C7220 mean?

The in-machine temperature sensor (in-machine thermistor) tells the main/engine PWB how warm it is inside the printer. C7220 appears when the sampled value from it goes past the reference value. The manual checks the wiring, then the sensor, then the main board. The same code and the same checks apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, because Kyocera covers all of them in one service manual.

What causes C7220?

  • Loose connector or damaged wire

    The lead from the in-machine temperature sensor to the main/engine PWB (YC1) is not making good contact.

  • Faulty in-machine temperature sensor

    The sensor itself has failed.

  • Main/engine PWB fault

    The main control board is faulty. The manual lists this last.

What can you check yourself?

  1. 1

    Restart once

    Switch the printer off at the power switch, wait a few seconds and switch it on again. Note the code shown.

  2. 2

    If the code returns

    Leave the printer off and call a technician. The remaining checks are inside the machine.

Safety: The manual says to pull the power plug out of the wall socket before taking any cover off. After the work, check that every connector, wire and screw that was removed has gone back in place.

Steps for a technician

  1. 1

    Check the connection

    Clean the contacts and refit the connector between the in-machine temperature sensor and the main/engine PWB (YC1). Fit a new wire if there is no continuity.

  2. 2

    Replace the sensor

    If the code stays, fit a new in-machine temperature sensor.

  3. 3

    Replace the main/engine PWB

    As the final step, fit a new main/engine PWB.

Need a part for this?

The store does not list the in-machine temperature sensor named for this code, so please ask on WhatsApp for availability.

Ask on WhatsApp: +91 88899-15080

When should you call a technician?

Call a technician if C7220 shows again after one restart. The checks need the sensor wiring and the main board reached.

Questions people ask

What does error C7220 mean on a Kyocera M2040dn?
On a Kyocera ECOSYS M2040dn, C7220 means broken in-machine thermistor. The reading from the sensor that measures the temperature inside the printer is beyond its reference value.
How do I fix Kyocera C7220?
A technician reseats the sensor connector at YC1 on the main/engine PWB, then replaces the in-machine temperature sensor if needed, and the main/engine PWB as the last step.
Is Kyocera C7220 a fuser error?
No. C7220 comes from the in-machine temperature sensor, not from the fuser sensors.
What is the difference between Kyocera C7220 and C7800?
C7220 comes from the sensor that reads the temperature inside the printer. C7800 comes from the temperature/humidity sensor that reads the outside air.