Shop parts
C0970Service codeCritical: machine stops

Kyocera ECOSYS M2040dn error C0970: power interruption detection

Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw

Quick answer

Kyocera ECOSYS M2040dn error C0970 is a power interruption detection error. The first thing the manual checks is the interlock switch, which should turn on when the right cover is closed. Make sure every cover is shut firmly, then do a full power reset. If C0970 stays, a technician checks the power board wiring.

What does C0970 mean?

C0970 tells you the printer detected a break in its power. The manual gives no more detail on how it is detected, but its checks start with the cover interlock switch and then move to the low voltage PWB, which supplies power, and the main/engine PWB. The same code and the same checks apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, because Kyocera covers all of them in one service manual.

What causes C0970?

  • Interlock switch not turning on

    The switch that senses the right cover is closed does not switch on.

  • Main/engine PWB not working correctly

    A temporary fault on the main board that a full power reset may clear.

  • Loose connector or damaged wire

    The lead from the low voltage PWB (YC103) to the main/engine PWB (YC20) is not making good contact.

  • Faulty low voltage PWB

    The power supply board has failed.

  • Faulty main/engine PWB

    The main control board is at fault. The manual lists this last.

What can you check yourself?

  1. 1

    Close all covers firmly

    Open and close the covers once and make sure each one clicks shut.

  2. 2

    Full power reset

    Turn the power switch off and pull out the power cord. Wait at least 5 seconds, plug it back in and switch on.

  3. 3

    If the code returns

    Leave the printer off, note the code shown on the panel and call a technician.

Safety: Before anyone checks the low voltage power supply PWB, the manual says to switch off, pull the plug and wait at least 5 seconds so the capacitors on the boards can discharge.

Steps for a technician

  1. 1

    Check the interlock switch

    Open and close the right cover and confirm the interlock switch turns on. If it does not, refit the switch.

  2. 2

    Reset the main power

    Switch off, unplug, wait 5 seconds, then reconnect the cord and switch on.

  3. 3

    Check the power board lead

    Clean the contacts and refit the connectors between the low voltage PWB (YC103) and the main/engine PWB (YC20). If the wire has no continuity, fit a new wire.

  4. 4

    Replace the low voltage PWB

    If the code stays, fit a new low voltage PWB.

  5. 5

    Replace the main/engine PWB

    As the final step, fit a new main/engine PWB.

Need a part for this?

The store does not list the interlock switch, low voltage PWB or main/engine PWB for this code, so please ask on WhatsApp for availability.

Ask on WhatsApp: +91 88899-15080

When should you call a technician?

Call a technician if C0970 stays after all covers are closed and the power has been reset. The next checks involve the interlock switch and the power boards.

Questions people ask

What does error C0970 mean on a Kyocera M2040dn?
On a Kyocera ECOSYS M2040dn, C0970 is a power interruption detection error. The manual's checks start with the cover interlock switch and then the power board.
How do I fix Kyocera C0970?
Close all covers firmly, then switch off, unplug for 5 seconds and switch on. If C0970 stays, a technician checks the interlock switch, the low voltage PWB lead and the boards.
Can a faulty cover switch cause Kyocera C0970?
Yes. The Kyocera service manual's first check is whether the interlock switch turns on when the right cover is opened and closed.