Kyocera ECOSYS M2040dn error C6650: thermopile EEPROM error
Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw
Quick answer
Kyocera ECOSYS M2040dn error C6650 means the printer cannot access the EEPROM memory in the thermopile, the sensor that reads the fuser belt temperature. The manual's first suspect is a weak power supply. Plug the printer straight into its own wall socket, not a multi-plug, then call a technician if it returns.
What does C6650 mean?
The thermopile has its own small EEPROM memory chip. C6650 appears when the main/engine PWB cannot access it. The manual checks the mains supply first, then the thermopile wiring, the thermopile and the main/engine PWB. The same code and the same checks apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, because Kyocera covers all of them in one service manual.
What causes C6650?
Low supply voltage
The mains voltage has dropped more than 10% below the rated voltage, or the printer runs from a multiple tap.
Loose connector or damaged wire
The lead from the thermopile to the main/engine PWB (YC2) is not making good contact.
Faulty thermopile
The thermopile, which holds the EEPROM, has failed.
Main/engine PWB fault
The main control board is faulty. The manual lists this last.
What can you check yourself?
- 1
Use a direct wall socket
Unplug the printer from any multi-plug or extension board and plug it straight into a wall socket.
- 2
Restart
Switch the printer off, wait a few seconds and switch it on again.
- 3
If the code returns
Leave the printer off and call a technician. The next checks are inside the machine.
Steps for a technician
- 1
Check the power source
If the supply voltage drops more than 10% of the rated voltage or a multiple tap is in use, change the power supply.
- 2
Check the connection
Clean the contacts and refit the connector between the thermopile and the main/engine PWB (YC2). Fit a new wire if there is no continuity.
- 3
Replace the thermopile
If the code stays, fit a new thermopile.
- 4
Replace the main/engine PWB
As the final step, fit a new main/engine PWB.
Need a part for this?
The store does not list the thermopile for this model yet. Message us on WhatsApp and we will check availability for you.
Ask on WhatsApp: +91 88899-15080When should you call a technician?
Call a technician if C6650 returns with the printer plugged straight into a wall socket. The later checks need the thermopile wiring and boards reached.
Questions people ask
- What does error C6650 mean on a Kyocera M2040dn?
- On a Kyocera ECOSYS M2040dn, C6650 is a thermopile EEPROM error. The printer cannot access the memory chip in the fuser temperature sensor.
- Can a multi-plug cause Kyocera C6650?
- Yes. The Kyocera service manual checks the power supply first and treats a multiple tap or a voltage drop of more than 10% as a cause.
- How do I fix Kyocera C6650?
- Plug the printer straight into a wall socket and restart. If C6650 stays, a technician checks the thermopile connector at YC2, then replaces the thermopile, and the main/engine PWB last.
- Is Kyocera C6650 related to C6030?
- Both involve the thermopile. C6030 means its temperature signal is abnormal, while C6650 means its EEPROM cannot be read.