Shop parts
ProblemWarning

Kyocera ECOSYS M2040dn part of the image missing or white patches

Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw

Quick answer

When part of the image is missing on a Kyocera ECOSYS M2040dn, the cause is either the scan or the print. Print the Test Page from Service Setting. If only copies lose part of the page, check how the original is placed and set the original size by hand. If prints show white patches, try fresh dry paper first.

What is happening?

On copies, a missing area usually means the original was placed wrongly, its size was detected wrongly, or the glass is dirty. Highlighter marks and shiny spots on the original can also drop out. On prints, white spots or blank areas often come from damp paper, the wrong media type, a dirty drum or a dirty transfer roller. The same checks apply to all eight models in this service manual.

What causes it?

  • Original content or placement

    Highlighter marks that do not scan, light reflecting off the original, or an original not placed properly.

  • Size mismatch

    The original size and paper size do not match on the panel, sometimes because the DP original detection sensor misreads.

  • Dirty or loose glass

    A dirty or loose contact glass or slit glass.

  • Scanner hardware

    A loose CIS or DPCIS cable, a loose scanner carriage, a faulty CIS or DPCIS, or the main/engine PWB.

  • Damp paper or wrong media type (engine)

    Paper kept in a humid place, or a media type that does not match the paper.

  • Drum or transfer roller (engine)

    A dirty drum surface, or a dirty, scratched or bent transfer roller.

What can you check yourself?

  1. 1

    Print the test page

    Go to System Menu > Adjustment/Maintenance > Service Setting and print the Test Page (a grey halftone sheet). If the fault is on the test page, the printing engine is the cause. If the test page is clean and only copies or scans show it, the scanner is the cause.

  2. 2

    Place the original again

    Reload the original properly and set the original size manually on the panel.

  3. 3

    Change the image quality

    If highlighter marks disappear, change the original image quality in the System Menu.

  4. 4

    Clean the glass

    Wipe the contact glass, the narrow slit glass beside it and the white original mat under the cover. Copy again.

  5. 5

    Use dry paper

    Load fresh paper from a sealed pack and set the right media type for the cassette or MP tray in the System Menu. Keep spare paper sealed in a plastic bag in a dry place.

Safety: The manual says to pull the power plug before taking anything apart, to handle the charger sections with care because they carry high voltage, and never to open the laser optical unit (LSU) because the laser can harm eyesight. Users should stay with settings, paper, toner and glass cleaning.

Steps for a technician

  1. 1

    Isolate scanner or engine

    Print the Test Page from Service Setting. A fault on the test page is an engine factor; a clean test page means a scanner factor. A fault that scales with zoom copying is also a scanner factor. On the scanner side, check whether it follows the contact glass, the DP front side (main unit CIS) or the DP back side (DPCIS, 40 ppm models only).

  2. 2

    Original and settings

    Set the image quality for highlighter originals, avoid reflective areas, reload the original and set the original size by hand.

  3. 3

    Glass

    Clean the scanning side of the contact glass, or the slit glass for DP scans, and refit the glass if it is loose.

  4. 4

    Scanner hardware

    Reseat the CIS FFC (YC506) or DPCIS cable, refit the scanner carriage, and replace the DP original detection sensor if it misreads the size. Replace the scanner carriage with U411 Table(ChartA) and DP FU(ChartA), or the DPCIS. Last, the main/engine PWB.

  5. 5

    Paper (engine)

    Replace damp paper, advise dry storage and set the correct media type.

  6. 6

    Drum and transfer roller

    Run Drum Refresh. If the fault repeats at one transfer roller turn, clean the roller; replace it if it is bent or still dirty.

Need a part for this?

The store does not list the transfer roller, DP original detection sensor or scanner parts named for this fault, so please ask on WhatsApp for availability.

Ask on WhatsApp: +91 88899-15080

When should you call a technician?

Call a technician if parts of the page are still missing after reloading the original, setting the size and using dry paper.

Questions people ask

Why is part of my copy missing on a Kyocera M2040dn?
The original may be placed wrongly or its size misread. Reload it and set the original size by hand. Also clean the contact glass or slit glass.
Why does my Kyocera print white spots?
Damp paper is the first cause the service manual lists. Use dry paper, set the right media type, and if that fails a technician checks the drum and transfer roller.
Highlighted text does not show on Kyocera copies?
The service manual says highlighter marks may not scan. Change the original image quality setting in the System Menu.

Related codes

See all Kyocera ECOSYS M2040dn error codes