Kyocera ECOSYS M2040dn prints or copies a blank white page
Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw
Quick answer
A blank white page from a Kyocera ECOSYS M2040dn means nothing was scanned or nothing was transferred to the paper. If only copies are blank, check the original is face the right way. Print the Test Page from Service Setting: a blank test page points to the engine, starting with the developer bias contact and high voltage.
What is happening?
When copies are blank but prints are fine, the scanner did not capture the image, often because the original was loaded upside down. When the test page is also blank, toner is not reaching the paper. Kyocera checks the transfer bias from the high voltage PWB, the developer bias contact, the developer drive, the laser unit cables and the boards. The same checks apply to all eight models in this service manual.
What causes it?
Original loaded the wrong way
The original was placed upside down, so the blank side was scanned.
Scanner not reading
A loose slit glass, DP scan position (U068) off, a loose home position sensor, CIS cable, scanner drive belt or drive gear, a faulty CIS or DPCIS, or the main/engine PWB.
No transfer bias (engine)
The main/engine PWB does not send the transfer high voltage on signal, or the high voltage PWB does not output transfer bias.
Developer bias or drive (engine)
A dirty or bent developer bias contact, a faulty developer unit side gear, or a developer clutch or drive that does not work.
Laser and high voltage (engine)
The LSU (APC PWB) cable to the main/engine PWB (YC505), the high voltage cable (YC16), the high voltage PWB, the APC PWB in the LSU, or the main/engine PWB.
What can you check yourself?
- 1
Check the original
Load the original face the correct way for the glass or the document processor and copy again.
- 2
Print the test page
Go to System Menu > Adjustment/Maintenance > Service Setting and print the Test Page (a grey halftone sheet). If the fault is on the test page, the printing engine is the cause. If the test page is clean and only copies or scans show it, the scanner is the cause.
Steps for a technician
- 1
Isolate scanner or engine
Print the Test Page from Service Setting. A fault on the test page is an engine factor; a clean test page means a scanner factor. A fault that scales with zoom copying is also a scanner factor. On the scanner side, check whether it follows the contact glass, the DP front side (main unit CIS) or the DP back side (DPCIS, 40 ppm models only).
- 2
Scanner side
Make sure the original is the right way up. For DP scans, refit the slit glass and adjust U068 [DP Read]. Refit the home position sensor and reseat the CIS FFC (YC506). Refit the scanner drive belt and drive gear.
- 3
Scanner hardware
Replace the scanner carriage and run U411 Table(ChartA) and DP FU(ChartA). For back sides on 40 ppm models, replace the DPCIS and run U411 [DP FD(ChartA)]. Then check the main/engine PWB connectors and board.
- 4
Transfer bias (engine)
If the main/engine PWB does not send the transfer high voltage on signal (5 V to 0 V), replace it. If the high voltage PWB does not output transfer bias, replace the high voltage PWB.
- 5
Developer (engine)
Clean or reshape the developer bias contact so it grounds well. Replace the developer unit if its side gear is faulty.
- 6
Cables
Reseat the LSU (APC PWB) FFC to the main/engine PWB (YC505), and clean and reseat the high voltage PWB cable (YC16). Replace any cable that is damaged or has no continuity.
- 7
Developer clutch
Refit the developer clutch and its connector; replace it if it still does not work.
- 8
Boards and LSU
Replace the high voltage PWB, then the LSU (APC PWB fault), then the main/engine PWB.
Need a part for this?
The store does not list the developer unit, LSU, high voltage PWB or main/engine PWB named for this fault, so please ask on WhatsApp for availability.
Ask on WhatsApp: +91 88899-15080When should you call a technician?
Call a technician if the test page comes out blank, or if copies stay blank after the original is loaded the right way.
Questions people ask
- Why does my Kyocera M2040dn print blank pages?
- If the Test Page is also blank, toner is not reaching the paper. The Kyocera service manual checks the transfer bias, the developer bias contact, the developer drive, the LSU and high voltage cables, and then the boards.
- Copies are blank but PC prints are fine?
- Then the scanner is not capturing the image. First check the original is not upside down. After that a technician checks the slit glass, scan position, home position sensor, drive belt and CIS.
- Is a blank page a toner problem on Kyocera M2040dn?
- The service manual does not list toner for a fully blank page. Faint or light pages are a separate fault, where toner is checked first.