Shop parts
J0519Paper jam codeWarning

Kyocera ECOSYS M2040dn J0519: multi-feeding from the MP tray

Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw

Quick answer

Kyocera ECOSYS M2040dn code J0519 means multi-feeding from the MP tray, the bypass tray: sheets fed together and the registration sensor stayed covered too long. Curled paper or a worn MP separation pad are likely causes. First remove the paper, fan it, take out bent sheets and reload a smaller stack.

What does J0519 mean?

When feeding from the MP tray, the registration sensor should turn off within a set time after the registration clutch engages. J0519 means it stayed on. The MP feed roller and MP separation pad are what keep sheets apart in this tray. The same code and steps apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, which share one Kyocera service manual.

What causes J0519?

  • Paper problems

    Crushed cut ends, bent edges, foreign matter, or curled or wavy paper.

  • MP separation pad not separating

    The MP feed roller and MP separation pad are dirty or worn.

  • Registration sensor actuator

    The actuator is bent or not moving properly.

  • Wiring

    Registration sensor (YC16) or registration clutch (YC10) connectors on the main/engine PWB.

  • Registration clutch stays engaged

    Paper reached the registration roller but shows no loop mark.

  • Registration sensor or main/engine PWB fault

    Checked last.

What can you check yourself?

  1. 1

    Switch off before reaching inside

    Turn the power switch off before you put your hands inside a cover or the cassette slot.

  2. 2

    Remove and reload the MP tray paper

    Take out all paper, remove bent sheets, fan the rest and reload with the guides touching the stack.

  3. 3

    Use paper within specification

    Damp, wavy, curled or out-of-specification paper is a common cause. Use fresh, dry paper of a supported type and keep spare paper in a dry place.

  4. 4

    Try again

    Close all covers, switch on and print a few pages. If the same code keeps coming back, stop and call a technician.

Safety: Switch off and unplug the machine before any cover is removed for repair. The manual warns that charge can stay in the low voltage PWB capacitors for a short time after unplugging, so wait at least 5 seconds before touching boards.

Steps for a technician

  1. 1

    Check the paper

    Fan crushed sheets, remove bent sheets and sheets with foreign matter, and correct or replace curled or wavy paper.

  2. 2

    Check the MP feed roller and MP separation pad

    Clean both surfaces or replace them.

  3. 3

    Check the registration sensor actuator

    Correct and refit a bent actuator, and replace it if needed.

  4. 4

    Check wiring

    Reseat registration sensor (YC16) and registration clutch (YC10) on the main/engine PWB.

  5. 5

    Check the registration clutch

    If there is no paper loop mark, refit or replace it.

  6. 6

    Check the registration sensor

    Clean it and reconnect; replace the high voltage PWB if it still fails.

  7. 7

    Replace the main/engine PWB

    As the last step.

Need a part for this?

The store does not list the MP feed roller or MP separation pad for this code, so please ask on WhatsApp if you need one.

Ask on WhatsApp: +91 88899-15080

When should you call a technician?

Call a technician if the MP tray keeps feeding double sheets with fresh, flat paper.

Questions people ask

What does J0519 mean on a Kyocera M2040dn?
J0519 on a Kyocera ECOSYS M2040dn means more than one sheet fed from the MP (bypass) tray, so the registration sensor stayed on too long.
Why does the Kyocera bypass tray feed two sheets at once?
The Kyocera manual points to the paper first, then to a dirty or worn MP feed roller and MP separation pad.
Is J0519 a different fix from J0509?
Yes. J0509 is a no feed from the MP tray and checks the lift cam and MP solenoid. J0519 is a double feed and checks the MP separation pad.

Related codes

See all Kyocera ECOSYS M2040dn error codes