A grey or dirty background on a Kyocera ECOSYS M2040dn means toner or scan noise is showing where the page should be white. Print the Test Page from Service Setting. If only copies are grey, set Background Density Adjustment to Manual and lower it. If the test page is grey, the developer bias contact is the first engine check.

What is happening?

On copies a grey background usually comes from a dark original, the background density setting, an original lifting off the glass, or a dirty shading plate that the scanner uses as its white reference. On prints, Kyocera checks the developer bias contact, a cold room, drum unit grounding, the main charger wire and the high voltage supply. The same checks apply to all eight models in this service manual.

What causes it?

  • Dark original or density setting

    The original has a dark background, or the background density adjustment is set too dark.

  • Original lifting

    The original is not flat on the glass while it is scanned.

  • Dirty shading plate or scanner set-up

    A dirty shading plate under the contact glass, U411 not run, a loose home position sensor or CIS cable.

  • Document processor parts

    A dirty or loose slit glass, a bent DP frame or faulty DP hinge, or on back sides a dirty or slow DP conveying roller A or faulty DPCIS.

  • Developer bias contact or cold room (engine)

    A dirty or bent developer bias contact, or a machine inside temperature of 16°C / 60.8°F or less.

  • Grounding, charger and high voltage (engine)

    A drum unit that is not grounded, a dirty main charger wire, the high voltage cable (YC16), the high voltage PWB contact, or the main/engine PWB.

What can you check yourself?

  1. 1

    Print the test page

    Go to System Menu > Adjustment/Maintenance > Service Setting and print the Test Page (a grey halftone sheet). If the fault is on the test page, the printing engine is the cause. If the test page is clean and only copies or scans show it, the scanner is the cause.

  2. 2

    Adjust background density

    In the System Menu, set Background Density Adjustment to Manual and lighten it, then copy again.

  3. 3

    Hold the original flat

    Press the original flat on the glass so it does not lift during the scan.

  4. 4

    Check the room

    If prints are grey too and the room is cold, move the printer to a place warmer than 16°C / 60.8°F, as the manual advises.

Safety: The manual says to pull the power plug before taking anything apart, to handle the charger sections with care because they carry high voltage, and never to open the laser optical unit (LSU) because the laser can harm eyesight. Users should stay with settings, paper, toner and glass cleaning.

Steps for a technician

  1. 1

    Isolate scanner or engine

    Print the Test Page from Service Setting. A fault on the test page is an engine factor; a clean test page means a scanner factor. A fault that scales with zoom copying is also a scanner factor. On the scanner side, check whether it follows the contact glass, the DP front side (main unit CIS) or the DP back side (DPCIS, 40 ppm models only).

  2. 2

    Scanner settings and original

    Set Background Density Adjustment to Manual. Make sure the original lies flat.

  3. 3

    Scanner reference and sensors

    Clean the shading plate under the contact glass. Run U411 [Table(ChartA)]. Refit the home position sensor and reseat the CIS FFC (YC506).

  4. 4

    Document processor

    Clean or refit the slit glass. Replace the document processor if its frame is bent or the hinge is faulty. For back sides, run U411 [DP FD(ChartA)], clean DP conveying roller A and refit its drive, then replace the DPCIS if needed.

  5. 5

    Scanner hardware

    Replace the scanner carriage (LED or CIS) and run U411 Table(ChartA) and DP FU(ChartA). Last, the main/engine PWB.

  6. 6

    Developer bias and temperature (engine)

    Clean or reshape the developer bias contact so it grounds well. If the inside temperature is 16°C / 60.8°F or less, ask the user to move the machine somewhere warmer.

  7. 7

    Drum grounding and charger

    Fit the main charger unit onto the drum unit and seat the drum unit in the machine so it is grounded. Clean the main charger wire, or replace the main charger unit.

  8. 8

    High voltage and board

    Clean and reseat the high voltage PWB to main/engine PWB cable (YC16), replace it if there is no continuity. Then replace the high voltage PWB, and last the main/engine PWB.

Need a part for this?

The store does not list the main charger unit, developer unit, high voltage PWB or scanner parts named for this fault, so please ask on WhatsApp for availability.

Ask on WhatsApp: +91 88899-15080

When should you call a technician?

Call a technician if the background stays grey after adjusting background density, or if the test page itself has a grey background.

Questions people ask

How do I remove the grey background on Kyocera M2040dn copies?
Set Background Density Adjustment to Manual in the System Menu and lighten it. If the Test Page is clean, the rest of the fix is on the scanner side, starting with the shading plate.
Why are my Kyocera prints grey in a cold office?
The service manual says a machine inside temperature of 16°C / 60.8°F or less can cause a grey background. Move the printer to a warmer room.
Does a grey background mean the toner is bad?
The Kyocera service manual does not list toner for this fault. It checks the developer bias contact, drum unit grounding, the main charger wire and the high voltage supply.