Kyocera ECOSYS M2040dn error C6000: broken fuser heater
Applies to: Kyocera ECOSYS M2040dn, Kyocera ECOSYS M2135dn, Kyocera ECOSYS M2635dn, Kyocera ECOSYS M2635dw, Kyocera ECOSYS M2735dw, Kyocera ECOSYS M2540dn, Kyocera ECOSYS M2540dw, Kyocera ECOSYS M2640idw
Quick answer
Kyocera ECOSYS M2040dn error C6000 means the fuser did not get hot enough, fast enough, during warm-up, so the printer stops and reports a broken fuser heater. The first thing to look for is a scrap of paper stuck in the fuser. If none is there, a technician checks the wiring and then the fuser unit.
What does C6000 mean?
While the printer warms up, it switches on the fuser heater and watches the temperature through the thermopile, a sensor that reads the fuser belt. C6000 appears if the reading stays under 100°C/212°F after 10 seconds of non-stop heating, or if it still has not reached print-ready temperature 30 seconds after passing 60°C/140°F. The same code and the same checks apply to the ECOSYS M2135dn, M2635dn, M2635dw, M2735dw, M2540dn, M2540dw and M2640idw, because Kyocera covers all of them in one service manual.
What causes C6000?
Paper left inside the fuser
A stuck piece of paper can block the thermopile, so it cannot read the real temperature.
Loose connector or damaged wire
Either the lead from the fuser unit to the main/engine PWB (YC19) or the lead from the low voltage PWB (YC103) to the main/engine PWB (YC20) is not making good contact.
Fuser heater has failed
The heater sits inside the fuser unit. The manual's fix is a new fuser unit, not a separate heater.
Low voltage PWB fault
The low voltage power supply board that feeds the heater is faulty.
Main/engine PWB fault
The main control board is faulty. The manual lists this last.
What can you check yourself?
- 1
Switch off and unplug
Turn the power switch off and remove the plug from the wall socket before you open any cover.
- 2
Look for stuck paper
Open the covers you normally use to clear paper jams and pull out any paper you can see near the fuser. The fixing area can be very hot, so do not touch metal parts and do not unscrew anything.
- 3
Try once more
Close the covers, plug in and switch on. If C6000 comes back, leave the printer off and call a technician.
Steps for a technician
- 1
Clear paper from the fuser
Remove any paper left in the fuser unit, since it stops the thermopile from reading correctly.
- 2
Check the connections
Clean the contacts and refit the connectors for fuser unit to main/engine PWB (YC19) and low voltage PWB (YC103) to main/engine PWB (YC20). If a wire has no continuity, fit a new wire.
- 3
Replace the fuser unit
If the code remains, treat the fuser heater as broken and fit a new fuser unit.
- 4
Replace the low voltage PWB
If a new fuser unit does not clear it, fit a new low voltage PWB.
- 5
Replace the main/engine PWB
As the final step, fit a new main/engine PWB.
Parts for this error
Fuser unit
Only if step 1 and step 2 do not clear C6000. The heater is inside the fuser unit, so the manual's measure at step 3 is to fit a complete fuser unit.
When should you call a technician?
Call a technician if C6000 shows again after you have cleared any visible paper. Every later step involves the fuser wiring, the fuser unit or the power boards.
Questions people ask
- What does error C6000 mean on a Kyocera M2040dn?
- On a Kyocera ECOSYS M2040dn, C6000 means the fuser did not reach the expected temperature in time during warm-up, so the printer reports a broken fuser heater and stops.
- How do I clear Kyocera C6000?
- Switch the printer off, unplug it and remove any paper you can see near the fuser, taking care because it can be very hot. If C6000 returns after you switch back on, a technician needs to check the fuser wiring and the fuser unit.
- Does Kyocera C6000 always mean a new fuser unit?
- No. The Kyocera service manual first checks for stuck paper and loose connectors, and only then replaces the fuser unit. The low voltage PWB and the main/engine PWB are checked after that.
- Can I replace the fuser heater on its own in a Kyocera M2040dn?
- The Kyocera service manual does not replace the heater by itself for C6000. Its measure is to fit a complete fuser unit, which contains the heater.